Dynamic data is the part of the battery passport that cannot be filled in at the factory. State of health, capacity and power fade, state of certified energy, cycles, negative events, temperature and state of charge histograms: these are data points 51 to 71 of the Commission guidance, all drawn from Annex XIII point 4 of Regulation (EU) 2023/1542. The texts say what to publish and to whom. They set no update frequency, and they provide no exemption for a BMS that cannot produce the data. Status as of 26 November 2026.

During the Commission webinar of November 2026, 343 questions were asked. 30 were on this theme. We do not know the answers given orally: this article sets out our reading of the texts and flags what remains open.

Two questions sum up the concern:

"We have BMS with limited memory, and we can't modify the parameters they send. How should we handle variables required by BP that these models cannot provide?"

"How often the dynamic data needs to be updated? Is there a strict requirement?"

The second was asked many times, in different forms.

What the texts actually require

Annex XIII, point 4 lists data specific to each individual battery, accessible only to persons with a legitimate interest (and to authorities, see the battery passport data access levels):

  • •4(a) the values for the performance and durability parameters, "when the battery is placed on the market and when it is subject to changes in its status";
  • •4(b) the state of health, pursuant to Article 14;
  • •4(c) the status: "original", "repurposed", "re-used", "remanufactured" or "waste";
  • •4(d) usage data: charging and discharging cycles, negative events such as accidents, and periodically recorded temperature and state of charge.

The Commission guidance (version 4, 19 November 2026) breaks this point down into 21 data points:

PointsContentSource
51 to 60Capacity, capacity fade, power, power fade, internal resistance and its increase, energy round-trip efficiency and its fade (where applicable), expected lifetime in cycles and in yearsAnnex XIII 4(a)
61State of certified energy (SOCE)Annex XIII 4(b)
62 to 66Remaining capacity, remaining power capability, remaining round-trip efficiency, self-discharge evolution, ohmic resistanceAnnex XIII 4(b)
67Status of the batteryAnnex XIII 4(c)
68 to 71Cycles, negative events, environmental conditions including temperature [histogram], state of charge [histogram, %]Annex XIII 4(d)

Two clarifications in the guidance matter for architecture. Its Remark A states that the dynamic dimension of points 51 to 60 reflects that these parameters "may need to be updated where there is a status change of the battery, e.g. repurposed or remanufactured". And points 68 to 71, including the state of charge histogram (point 71), are marked "applicable as soon as the battery starts to be used" for all three categories.

Article 14 adds a hardware obligation: since 18 August 2024, the BMS of stationary battery energy storage systems, LMT and EV batteries contains state of health data. Access is read-only and non-discriminatory, for the person who legally purchased the battery, independent or waste management operators, or a third party acting on their behalf. The purposes are listed: energy aggregation, evaluating residual value and lifetime, re-use, repurposing, remanufacturing.

How often must the data be updated?

Short answer: no fixed frequency appears in the Regulation or in guidance v4, in the sources we have verified. The word "periodically" in points 70 and 71 comes with no period.

The texts do, however, distinguish two triggers:

Data typeTrigger set by the textsFixed period
Performance and durability (51 to 60)Placing on the market, then status change (Remark A)None
Status (67)Status changeNone
State of health (61 to 66)Reference to Article 14None
Usage (68 to 71)Periodic recording, from first useNone

The general rule remains Article 77(4): the operator ensures the information is accurate, complete and up to date. With no regulatory period, it is for the operator to show that its practice meets that requirement.

Our recommendation: define an update policy per data category, write it down, justify it and have it validated by legal counsel. For example: event-driven updates for status and negative events, periodic updates for histograms, and an update at every service visit for values measured in the workshop. The policy can be adjusted if the Article 77(9) implementing act or a future version of the guidance clarifies the point.

When the BMS cannot provide the data

Participants described very concrete situations: BMS with limited memory, parameters that cannot be changed, long development cycles. One noted that the requirement of a histogram for state of charge and temperature "is not found in the Battery Regulation directly" and would be impossible to implement quickly in a BMS. That is accurate on one point: the Regulation speaks of periodically recorded state of charge; the histogram format comes from the guidance, which is not binding.

The texts provide no exemption for missing technical capability. For points 63 to 66, the guidance item names include "where possible"; the scope of these words is not specified.

Practical options, to be read as such and not as compliance guarantees:

  1. 01.Collection through the BMS or telematics, where a read API exists.
  2. 02.Recording during service visits: maintenance, diagnostics, status change.
  3. 03.Documented justification of what cannot be produced, and why.
  4. 04.A BMS evolution plan for the next product generations.

Another question raised: if the customer never connects the system to the cloud, who is responsible? Article 77(4) places the obligation on the economic operator that places the battery on the market; written authorisation to a third party does not transfer the ultimate legal responsibility (batteries FAQ 2.1). On our reading, the Regulation places no explicit obligation on end users. Data collection is therefore a matter for contracts, and the case of a battery that is never connected remains open. See who is responsible for the battery passport.

What applies by category

Based on guidance v4 and Article 14:

CategoryArt. 14 (BMS)SOCE (61)Points 62 to 66Points 52 to 56Usage (68 to 71)
EVYesMandatoryNot to be filledMandatoryFrom first use
LMTYesNot to be filledMandatoryMandatoryFrom first use
Industrial > 2 kWh, stationary storage with BMSYesNot to be filledMandatoryRechargeable batteriesFrom first use
Industrial > 2 kWh, other useNot covered by Art. 14Not to be filledNo (stationary with BMS only)Rechargeable batteriesFrom first use
Industrial lead-acid without BMSTo be confirmedNot to be filledNo, per the guidance ("with a BMS" condition)Rechargeable batteriesTo be confirmed: the guidance does not address the no-BMS case

The last case came up during the webinar: industrial lead-acid batteries without a BMS, for which external monitoring is only available on a paid subscription. The texts do not say how to produce points 68 to 71 in that configuration. This is a point to validate with legal counsel.

On points 61 to 66, one participant asked whether the absence of harmonised standards for state of health calculation would lead to a delay. As of 26 November 2026, guidance v4 provides no postponement of these points.

What a platform must be able to do

Dynamic data requires three capabilities:

  • •ingest from several sources: BMS or telematics APIs, after-sales files, workshop records;
  • •keep the history: every value dated and versioned, every status change traced, which makes the update policy demonstrable;
  • •restrict access: points 51 to 71 are reserved for legitimate interest and authorities, never public.

Before February 2027, test these flows on real batteries, not only the static core: see how to test your battery passport before 2027.

In summary

Battery passport points 51 to 71 are required, restricted to legitimate interest, and mostly fed after sale. The texts set triggers (placing on the market, status change, periodic recording) but no frequency, and no exemption for a limited BMS. The right response is not to wait for clarification: it is a written update policy, identified collection sources per category, and legal validation of edge cases. The full list of 71 points is in our reading of the guidance.

Arianee runs an open DPP infrastructure that receives data from BMS, telematics or after-sales, keeps its history and enforces the Article 77 access rights. See our Battery Pass page or request a demo.

Sources: Regulation (EU) 2023/1542, Articles 14 and 77 and Annex XIII (EUR-Lex) · Guidance Document: Digital Batteries Passport – data points by category, version 4, 19 November 2026 (PDF, European Commission) · Digital Product Passport batteries FAQ, European Commission · Digital Product Passport — Batteries, European Commission. Participant questions: Q&A of the Commission webinar of November 2026, quoted anonymously.

From your product to its passport

Your batteries. Your deployment.

Discuss your battery categories, data sources and access rights with François Pujo.

François Pujo

François Pujo

Industrial & Battery Project Manager

Explore the platform first →

Let’s talk about your project

A demo based on your products and your data.

You are…